  • Regenerative Grid Simulator

    61800 - Chroma Systems Solutions, Inc.

    Power rating: Up to 300kVA, single or three phase outputOutput Voltage: 0~330V L-N / 0~570V L-L0~400V L-N / 0~692V L-L opt. without using a transformerOutput Frequency: DC, 30Hz~100HzMaximum power delivered down to 200VAC L-NFull 4 quadrant, fully regenerative up to 100% of output current ratingSpecifically designed for PV inverter, Smart Grid and EV related test applicationsProgrammable slew rate settings for voltage and frequencyProgrammable voltage and current limitsTurn on, turn off phase angle controlLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetParallel output for higher power applications (three phase only)

  • ±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester

    HBM-S1-B - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm

  • High Power Programmable AC Source with Transients

    61510 - Chroma Systems Solutions, Inc.

    Power Rating:61511: 12KVA61512: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • Lightning Current Generator

    Shanghai Guantu Technology Co., Ltd.

    The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.

  • Low Power Programmable AC Source with Transients

    61500 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface